Analisis Penurunan Tekanan Fluida di Dalam Pipa Antara Hotwell Pump (HWP) dan Menara Pendingin pada Pembangkit Listrik Tenaga Panas Bumi Lahendong Unit-2

Main Article Content

I Wayan Rikiawan
Rolles Nixon Palilingan
Alfrie Musa Rampengan

Abstract

A geothermal power plant (PLTP) is a power plant that utilizes geothermal fluid as its primary energy source. The fluid flowing in the PLTP component undergoes a change in magnitude which is very important to know, one of which is the pressure drop. Pressure drop is an essential term that can describe the pressure drop at a point in the pipe caused by particle friction in the fluid, fluid acceleration, and flow pipe elevation. An analysis of the pressure drop in the pipe between the hot well pump (HWP) and the cooling tower was carried out using the Harriston-Freeston method, which was made on Pressure Drop Modeling using a module program and visual basic. This program study the pressure drop in the pipe from the hot well pump (HWP) to the cooling tower as outlined in the form of a graph where the pressure drop along the pipe, both between hot well pump A and hot well pump B, as well as hot well pump B and cooling towers having a significant pressure drop. In the pipeline between hot well pump A and hot well pump B, the pressure is from 3.6 bar to 3.4 bar. Likewise, the pipeline between hot well pump B and the cooling tower also experiences the same pressure drop, namely at a pressure of 3.4 bar to a pressure of 1 bar. This thing is influenced by the pipe diameter. There is a reduction in diameter and particle friction in the fluid, fluid motion acceleration, and flow pipe elevation in certain pipelines.

Article Details

How to Cite
Rikiawan, I. W., Palilingan, R. N., & Rampengan, A. M. (2022). Analisis Penurunan Tekanan Fluida di Dalam Pipa Antara Hotwell Pump (HWP) dan Menara Pendingin pada Pembangkit Listrik Tenaga Panas Bumi Lahendong Unit-2. Jurnal FisTa Fisika Dan Terapannya, 3(1), 13-19. https://doi.org/10.53682/fista.v3i1.164
Section
Articles

References

Brehme, M., Moeck, I., Kamah, Y., Zimmermann, G., & Sauter, M. (2014). A Hydrotectonic Model Of A Geothermal Reservoir-A Study In Lahendong Indonesia, University Of Gottingen, Applied Geology Gold Schmidtstr.3,37077 Gottingen, Germany. 228-239.
Fauzi, A. Daniel., & Rudiyanto, Bayu (2016) Analisa Performa Menara Pendingin Pada Pt. Geo Dipa Energi Unit DiengJurusan Teknik, Politeknik Negeri Jember. (ISSN 2540-8704)
Fitriono, Azis. Azis & Santoso Agus (2020) Studi Pengaturan Kecepatan Motor Hotwell Pump (HWP) Terhadap Efesiensi Penggunaan Daya Listrik PTPLN (PERSERO) PLTP Ulubelu. Prodi Teknik Electro, Fakultas Teknik Universitas Muhammadiyah Lampung, Jurnal Ilmiah, 2746-1750
Hasibuan, S. Riadi Ahmad, Bahruddin, & Fadli Ahmad J (2014) Evaluasi Pressure Drop Pada Sumur Injeksi Uap Di Lapangan Duri Dengan Persamaan Beggs-Brill Dan Moody. Jurusan Teknik Kimia, Fakultas Teknik, Universitas Riau
Mulyana, C., & Riyandi, N. (2019). Model Pengaruh Diameter Pipa Terhadap Pressure Drop Pada Pipa Pltp Dominasi Uap, Departemen Fisika Fakultas Mipa Universitas Padjadjaran.26-32.
Polii, J. (2017). Pemodelan Penurunan Tekanan Brine Di Dalam Pipa Injeksi Pada Lapangan Panas Bumi Dieng, Universitas Negeri Manado Fmipa Jurusan Fisika. 32-35.Richardson, I., Addison, S., & Thompson, G. (2013).Steam PurityConsiderations In Geothermal Power Generation.
Saptadji, N. M. (2001).. Teknik Panasbumi. Institut Teknologi Bandung
Saptadji, N. M. (2020)..Teknik Geotermal 2nd edition Institut Teknologi Bandung
Tambahani, R. M. (2020). Pemodelan Penurunan Tekanan Fluida Di Dalam Pipa Antara Demister Dan Turbin Pada Pembangkit Listrik Tenaga Panas Bumi Lahendong Unit-2. Universitas Negeri Manado Fmipa Jurusan Fisika. Skripsi